More resistant to corrosion
For fault detection
5 Years (indoor and outdoor unit)
Low noise down to
Keep internal side dry, prevent bacteria
Air force up to a long distance
Rated Capacity, Cooling | 18000(T1) / 15900(T3) BTU |
---|---|
Rated Capacity, Heating | / |
Rated Running Current, Cooling | 9.4 A |
Rated Running Current, Heating | / |
Max. Input Power | 2500 W |
Max. Input Current | 13 A |
SEER Cooling | 2.04 W/W |
SCOP Heating | / |
Power Supply Source | 220~240V/50HZ |
Refrigerant | R22 |
Refrigerant Charged | 1170 g |
Max. Discharge Pressure | 3.2 Mpa |
Max. Suction Pressure | 0.8 Mpa |
Air Flow Volume | 950 m3/h |
Indoor Unit Noise Power | 44 dB(A) |
Outdoor Unit Noise Power | 58 dB(A) |
Indoor Unit Weight (Net) | 14 Kg |
Outdoor Unit Weight (Net) | 53 Kg |
Indoor Evaporator Bend | 3 |
Indoor Evaporator Row | 2 |
Indoor Evaporator Pipe Diameter | 7*0.24 mm |
Indoor Fan Motor | YYK30-4 |
Indoor Net Dimension | 952*310*227 mm |
---|---|
Indoor Packing Dimension | 1020*375*305 mm |
Liquid Valve | Φ6.35*0.5 mm |
Gas Valve | Φ12.7×0.7 mm |
Outdoor Compressor Brand | KK |
Outdoor Compressor Model | AW5522 |
Outdoor Fan Motor | YDK69-6B |
Outdoor Condenser Pipe Diameter | 9.52*0.27 mm |
Outdoor Condenser Row | 1 |
Outdoor Net Dimension | 800×690×300 mm |
Outdoor Packing Dimension | 935*415*760 mm |
Container Loading 40HC | 165 Units |
5 Years (indoor and outdoor unit)
Low noise down to
More resistant to corrosion
For fault detection
Keep internal side dry, prevent bacteria
Air force up to a long distance
Rated Capacity, Cooling | 23900(T1) / 21200(T3) BTU |
---|---|
Rated capacity, Heating | / |
Rated Running Current, Cooling | 13.5 A |
Rated Running Current, Heating | / |
Max. Input Power | 3380 W |
Max. Input Current | 17.5 A |
SEER Cooling | 2.06 W/W |
SCOP Heating | / |
Power Supply Source | 220~240V/50HZ |
Refrigerant | R22 |
Refrigerant Charged | 1700 g |
Max. Discharge Pressure | 3.2 Mpa |
Max. Suction Pressure | 0.8 Mpa |
Air Flow Volume | 1250 m3/h |
Indoor Unit Noise Power | 48 dB(A) |
Outdoor Unit Noise Power | 59 dB(A) |
Indoor Unit Weight (Net) | 17 Kg |
Outdoor Unit Weight (Net) | 57 Kg |
Indoor Evaporator Bend | 3 |
Indoor Evaporator Row | 2 |
Indoor Evaporator Pipe Diameter | 7*0.24 mm |
Indoor Fan Motor | YYK50-4 |
Indoor Net Dimension | 1082*330*233 mm |
---|---|
Indoor Packing Dimension | 1155*397*312 mm |
Liquid Valve | Φ6.35*0.5 mm |
Gas Valve | Φ15.88×0.75 mm |
Outdoor Compressor Brand | KK |
Outdoor Compressor Model | AW5530 |
Outdoor Fan Motor | YDK69-6B |
Outdoor Condenser Pipe Diameter | 9.52*0.27 mm |
Outdoor Condenser Row | 2 |
Outdoor Net Dimension | 800×690×300 mm |
Outdoor Packing Dimension | 935*415*760 mm |
Container Loading 40HC | 150 Units |
Keep internal side dry, prevent bacteria
Air force up to a long distance
More resistant to corrosion
For fault detection
5 Years (indoor and outdoor unit)
Low noise down to
Rated Capacity, Cooling | 29300(T1) / 26800(T3) BTU |
---|---|
Rated capacity, Heating | / |
Rated Running Current, Cooling | 17.5 A |
Rated Running Current, Heating | / |
Max. Input Power | 4400 W |
Max. Input Current | 23 A |
SEER Cooling | 2.75 W/W |
SCOP Heating | / |
Power Supply Source | 220~240V/50HZ |
Refrigerant | R22 |
Refrigerant Charged | 2100 g |
Max. Discharge Pressure | 3.2 Mpa |
Max. Suction Pressure | 0.8 Mpa |
Air Flow Volume | 1600 m3/h |
Indoor Unit Noise Power | 52 dB(A) |
Outdoor Unit Noise Power | 60 dB(A) |
Indoor Unit Weight (Net) | 18 Kg |
Outdoor Unit Weight (Net) | 64 Kg |
Indoor Evaporator Bend | 3 |
Indoor Evaporator Row | 2 |
Indoor Evaporator Pipe Diameter | 7*0.24 mm |
Indoor Fan Motor | D-310-50 |
Indoor Net Dimension | 1250*360*253 mm |
---|---|
Indoor Packing Dimension | 1340*445*355 mm |
Liquid Valve | Φ6.35*0.5 mm |
Gas Valve | Φ15.88×0.75 mm |
Outdoor Compressor Brand | KK |
Outdoor Compressor Model | AW5538 |
Outdoor Fan Motor | YDK85-6E |
Outdoor Condenser Pipe Diameter | Φ7*0.24 mm |
Outdoor Condenser Row | 2 |
Outdoor Net Dimension | 902×795×332 mm |
Outdoor Packing Dimension | 1030×860×430 mm |
Container Loading 40HC | 110 Units |
Air force up to a long distance
Low noise down to
5 Years (indoor and outdoor unit)
For fault detection
Keep internal side dry, prevent bacteria
More resistant to corrosion
Rated capacity, Cooling | 33500(T1) / 31800(T3) BTU |
---|---|
Rated capacity, Heating | / |
Rated Running Current, Cooling | 18.5 A |
Rated Running Current, Heating | / |
Max. Input Power | 5000 W |
Max. Input Current | 26.5 A |
SEER Cooling | 2.87 W/W |
SCOP Heating | / |
Power Supply Source | 220~240V/50HZ |
Refrigerant | R22 |
Refrigerant Charged | 2750 g |
Max. Discharge Pressure | 3.2 Mpa |
Max. Suction Pressure | 0.8 Mpa |
Air Flow Volume | 1600 m3/h |
Indoor Unit Noise Power | 52 dB(A) |
Outdoor Unit Noise Power | 60 dB(A) |
Indoor Unit Weight (Net) | 18 Kg |
Outdoor Unit Weight (Net) | 68 Kg |
Indoor Evaporator Bend | 3 |
Indoor Evaporator Row | 2 |
Indoor Evaporator Pipe Diameter | 7*0.24 mm |
Indoor Fan Motor | D-310-50 |
Indoor Net Dimension | 1250*360*253 mm |
---|---|
Indoor Packing Dimension | 1340*445*355 mm |
Liquid Valve | Φ6.35*0.5 mm |
Gas Valve | Φ15.88×0.75 mm |
Outdoor Compressor Brand | KK |
Outdoor Compressor Model | AW5542 |
Outdoor Fan Motor | YDK85-6E |
Outdoor Condenser Pipe Diameter | Φ7*0.24 mm |
Outdoor Condenser Row | 2 |
Outdoor Net Dimension | 902×795×332 mm |
Outdoor Packing Dimension | 1030×860×430 mm |
Container Loading 40HC | 110 Units |